- Supporting protocol for PROFINET IO:No
- Number of HW-interfaces parallel:0
- Supporting protocol for other bus systems:Yes
- Number of digital inputs:4
- Type of output voltage:DC
- Type of electric connection:Flat plug-in connection
- Supply voltage DC:0 - 28.8
- Fieldbus connection over separate bus coupler possible:Yes
- Supporting protocol for ASI:No
- Number of interfaces PROFINET:0
- Supporting protocol for EtherNet/IP:No
- Short-circuit protection, outputs available:No
- Supporting protocol for Data-Highway:No
- Supporting protocol for SERCOS:No
- Number of HW-interfaces serial TTY:0
- Number of HW-interfaces Wireless:0
- Supporting protocol for INTERBUS-Safety:No
- Radio standard Wi-Fi 802.11:No
- Supporting protocol for DeviceNet:No
- Degree of protection (IP):IP20
- Supporting protocol for INTERBUS:No
- SIL according to IEC 61508:None
- System accessory:Yes
- Supporting protocol for LON:No
- Number of HW-interfaces industrial Ethernet:0
- Wall mounting/direct mounting:Yes
- Rail mounting possible:Yes
- Supporting protocol for DeviceNet Safety:No
- Supporting protocol for PROFINET CBA:No
- Number of HW-interfaces other:0
- Number of HW-interfaces USB:0
- Supporting protocol for PROFIsafe:No
- Suitable for safety functions:No
- Supporting protocol for KNX:No
- Permitted voltage at output:0 - 0
- Supporting protocol for SafetyBUS p:No
- Supporting protocol for CAN:No
- Number of digital outputs:0
- Radio standard UMTS:No
- Explosion safety category for gas:None
- Input current at signal 1:4
- Number of HW-interfaces RS-485:0
- Rack-assembly possible:No
- Front built-in possible:No
- Radio standard GSM:No
- Appendant operation agent (Ex ib):No
- Supporting protocol for MODBUS:No
- Number of HW-interfaces RS-232:0
- Number of HW-interfaces RS-422:0
- Appendant operation agent (Ex ia):No
- Supporting protocol for Foundation Fieldbus:No
- Supporting protocol for SUCONET:No
- Supporting protocol for AS-Interface Safety at Work:No
- Supporting protocol for TCP/IP:No
- Type of digital output:None
- Voltage type of supply voltage:DC
- Explosion safety category for dust:None
- Radio standard Bluetooth:No
- With optical interface:No
- IO link master:No
- Radio standard GPRS:No
- Digital outputs configurable:No
- Supporting protocol for PROFIBUS:No
- Depth:102
- Width:35
- Height:90